In the “Power & water” step of the request form you state how much power your devices need and book the matching connections. Aetherial checks straight away whether the booked connections are enough.

In some categories (e.g. arts and crafts) the step is optional: you then see “Power & water (optional)” and can submit without this step.

  1. Total power of your devices in kW, for example “14.2”. Below that you can list your devices, e.g. “fryer 9 kW, cooling 2 kW”.
  2. Power connections: use − and + to set how many connections of each type you need (at most 9 per type).
  3. Refrigerated vehicle connections (separate): connections only for your refrigerated vehicle. If you entered a refrigerated vehicle in the Setup step, book at least one refrigerated vehicle connection here or tick “Refrigerated vehicle needs no power” (locked while a refrigerated vehicle connection is booked). Otherwise you can neither save the step nor submit the stand request, even if the step is optional for your category.
  4. Water connection ½ inch: tick it if you need water.
  5. Tap “Next” to save the step.

Next to each connection you see its power and the price from the event’s price list. On the right (or below on a phone), “Additional costs (net)” shows the total of your selection.

Connection Power
230 V · 16 A Schuko 3.3 kW
400 V · 16 A CEE 10.5 kW
400 V · 32 A CEE 21 kW
400 V · 63 A CEE 41.5 kW

For refrigerated vehicles there are 230 V · 16 A Schuko and 400 V · 16 A CEE.

As soon as you enter a device power, Aetherial compares it with the total of your booked power connections. Refrigerated vehicle connections don’t count.

  • If the power is enough, you see for example “21 kW booked, sufficient for 14.2 kW.”
  • If it isn’t, a red-outlined notice appears, e.g. “Booked 10.5 kW, needed 14.2 kW.”, with a button such as “Choose 400 V · 32 A CEE”.

Tapping the button replaces your power connections with the suggestion. Refrigerated vehicle connections and water stay as they are.

How the suggestion works:

  • Up to 41.5 kW: the smallest single connection that is enough. Example: 14.2 kW → 1 × 400 V · 32 A CEE.
  • Above that: as many 400 V · 63 A CEE as possible, plus the smallest connection for the rest. Example: 50 kW → 1 × 400 V · 63 A CEE + 1 × 400 V · 16 A CEE.
  • If more than 9 connections of one type would be needed, there is no suggestion. You then see: “More than you can book via the form – please talk to the agency.”

The agency later sees the same comparison in the stand list as the hint “Check kW” (see Rule hints).

Each connection and the water connection cost the price from the event’s price list. If a price is per day (“per day”), it counts for every event day. You find all totals under Costs.