Rule hints
Aetherial continuously checks the stands and vehicle access reports of an event against fixed rules. When a rule finds something, a hint appears as a small chip:
- in the “Checks” column of the stand list,
- in the header of the object detail view,
- for vehicle access reports in the list on the Vehicle access page,
- for banners in the banner plan (the banner’s row, a marked chip on the site plan).
Above the stand list, the “Check N hints” button sums up all hints; one click filters the list to rows with hints, a second click removes the filter.
A hint never blocks anything. It shows where someone should take a look.
The stand rules skip cancelled stands: they get no hint and cause none on other stands (duplicate number, distributor load, refrigerated truck spots). The warning when confirming a refrigerated truck and the warning at the start do not count them either. When a stand is reactivated, the rules apply again; see Cancelled.
Severity
Section titled “Severity”You can tell the severity by the symbol, not only by the colour:
| Symbol | Severity | Meaning |
|---|---|---|
| Triangle with ! (red outline) | Error | The data contradicts itself. Please correct it. |
| Circle with ! | Warning | Probably a problem. Please check. |
| Circle with i | Info | For your information, for example planning still open. |
All hints
Section titled “All hints”| Chip | Code | Severity |
|---|---|---|
| Duplicate no. | number_duplicate |
Error |
| Check kW | power_insufficient |
Warning |
| Setup time | setup_time_mismatch |
Warning |
| Test book expiring | test_book_expiring |
Error |
| Test book missing | test_book_missing |
Error |
| No cooling spot | cooling_power_without_spot |
Error |
| Cooling overbooked | cooling_spots_overbooked |
Warning |
| Distributor overloaded | distributor_overload |
Error |
| Distributor tight | distributor_tight |
Warning |
| No distributor | no_distributor |
Info |
| Towing vehicle > 3.5 t | towing_vehicle_heavy |
Info |
| Duplicate plate | plate_duplicate |
Error |
| Program changed | program_changed |
Warning |
| Banner missing | banner_missing |
Error |
| Late for milestone | task_late |
Error |
| Rule check failed | rule_error |
Error |
Hover over a chip and a tooltip explains the hint in one sentence, for example “This stand number is used more than once in the event.”
Duplicate no. (number_duplicate)
Section titled “Duplicate no. (number_duplicate)”Two or more stands in the same event share the same number. Upper/lower case and spaces at the start or end are ignored: “12a” and “ 12A ” count as equal. Stands without a number do not count. Every affected stand gets the hint – even one you are not allowed to see.
What to do: Give one of the stands a unique number in the object detail view. A common cause is a stand imported twice.
Check kW (power_insufficient)
Section titled “Check kW (power_insufficient)”In one time window (for example operation), the declared device power is higher than the power of the booked connections. Each connection counts as:
| Connection | Power |
|---|---|
| 16 A Schuko | 3.3 kW |
| 16 A CEE | 10.5 kW |
| 32 A CEE | 21 kW |
| 63 A CEE | 41.5 kW |
Example: a stand declares 12 kW of device power during operation but has booked only one 16 A CEE (10.5 kW).
What to do: Check with the exhibitor whether the device power is correct, or book a larger or additional connection. See also Power.
Setup time (setup_time_mismatch)
Section titled “Setup time (setup_time_mismatch)”The stand’s setup time window does not fall within any of the setup windows allowed for its category. The agency defines setup windows per category in the event settings (see Setup windows). If a category has no setup windows, nothing is checked.
What to do: Move the setup time into an allowed window together with the exhibitor or, if the exception is intended, leave the hint in place on purpose.
Test book expiring (test_book_expiring)
Section titled “Test book expiring (test_book_expiring)”The test book of the temporary structure (Fliegender Bau) is valid only until before the last day of the event (“valid until” is before the event end). Valid exactly until the last day is fine. Without “valid until” nothing is checked. The same hint appears on the Temporary structures page.
What to do: Request an extended test book from the exhibitor and update the date and copy.
Test book missing (test_book_missing)
Section titled “Test book missing (test_book_missing)”The stand has a temporary structure (Fliegender Bau) but no test book number or no copy of the test book (neither uploaded by the agency nor in the stand request). The same hint appears on the Temporary structures page.
What to do: Enter the test book number and upload the copy, or request it from the exhibitor.
No cooling spot (cooling_power_without_spot)
Section titled “No cooling spot (cooling_power_without_spot)”A power connection is booked as power for a cooling truck, but there is no “Refrigerated vehicle” requirement (cooling truck spot) in the same time window.
What to do: Add a cooling truck spot in the matching time window, or stop marking the connection as cooling power.
Cooling overbooked (cooling_spots_overbooked)
Section titled “Cooling overbooked (cooling_spots_overbooked)”More refrigerated trucks are confirmed in the sector (sum of their count) than the sector has refrigerated truck spots (see Sectors). Every stand of the sector with a confirmed refrigerated truck gets the hint. Without a value on the sector there is no limit. Requested trucks do not count.
What to do: Withdraw a confirmation in the object detail, move the stand to another sector, or adjust the sector’s spots.
Distributor overloaded (distributor_overload)
Section titled “Distributor overloaded (distributor_overload)”A power distributor that one of the stand’s connections is on is loaded above 100 %. The load is calculated as in the power plan: the connection power of all stands on the distributor times the simultaneity factor, divided by the distributor’s capacity. The threshold applies to the exact value: 100.2 % is an overload, even though the power plan shows a rounded “100 %”. Every stand on the distributor gets the hint.
What to do: In the power plan, move a connection to another distributor (the power plan suggests one) or use a larger distributor.
Distributor tight (distributor_tight)
Section titled “Distributor tight (distributor_tight)”A power distributor that one of the stand’s connections is on is loaded at 95 % or more, but not above 100 %. Calculated as for “Distributor overloaded”, on the exact value: 94.8 % is not yet tight, even though the power plan shows a rounded “95 %”.
What to do: Check whether more connections are coming; if so, move a connection first.
No distributor (no_distributor)
Section titled “No distributor (no_distributor)”At least one power connection of the stand is not yet assigned to a power distributor. This is for your information: distributor planning is still open.
What to do: Assign the connection to a distributor in the power plan.
Towing vehicle over 3.5 t (towing_vehicle_heavy)
Section titled “Towing vehicle over 3.5 t (towing_vehicle_heavy)”The permitted total weight of the vehicle that delivers the stand is over 3,500 kg (stated in the stand request or the master data). Such vehicles may not use every access route. This is for your information.
What to do: When placing stands, pick a spot with a suitable access route and agree the approach with the exhibitor.
Duplicate plate (plate_duplicate)
Section titled “Duplicate plate (plate_duplicate)”The same licence plate is reported or approved more than once in the event. The comparison ignores spaces, hyphens, dashes and upper/lower case: “SI - V 709” and “SIV709” are equal. Rejected and revoked reports do not count. Every affected report gets the hint.
What to do: Reject the duplicate report or merge the others into one report.
Program changed (program_changed)
Section titled “Program changed (program_changed)”An artist vehicle was taken over from the stage program and the act has since been moved or cancelled: the report’s day or time window no longer matches the program’s suggestion (2 h before the start until the end of the act). The report does not change by itself. Only reported and approved reports get the hint.
What to do: Open the report; it shows the new suggestion from the program. Adjust day and time window under “Edit”, or revoke or reject the report if the act was cancelled.
Banner missing (banner_missing)
Section titled “Banner missing (banner_missing)”The delivery deadline of the banner position has passed, but the banner’s status is not yet “Delivered” or later (it is still “File requested”, “File received”, “File approved” or “In print”). The agency sets the delivery deadline per position in the banner plan, for example two days before the milestone “Roof up”. Positions without a deadline, or with a milestone that has no time yet, are not checked. The hint shows in the banner’s row, the position is marked on the site plan, and the warning when starting the event counts the affected banners.
What to do: Follow up with the sponsor or the printer and set the status once the banner is delivered. If the deadline is wrong, change it at the position.
Late for milestone (task_late)
Section titled “Late for milestone (task_late)”The task is due before a milestone (“Done before”) but is not done yet, although the milestone is reached, its planned time has passed or lies before the task’s planned start. The hint shows in the task’s row under changeovers and tasks. Milestones without a time are only checked once they are reached.
What to do: Move the task earlier or get it done; if the milestone is wrong, clarify the time with the trade contractor.
Rule check failed (rule_error)
Section titled “Rule check failed (rule_error)”A rule could not be evaluated, usually because its configuration cannot be computed (for example an invalid setup window in the category). Aetherial shows this on purpose instead of silently assuming “no hints”: without this chip you might mistake a missing check for a passed one.
What to do: Check the category settings. If the hint stays, tell your administrator.